Master clock D201RQ/UPS/RACK

Master clock D201RQ/UPS/RACK

    The D201RQ / UPS time clock (main clock) is used to control secondary clock and digital clocks in a single time system at stations, manufacturing plants, schools, hotels, airports, shopping centers, offices, etc. It is fully backed up to ensure continuous operation

C485 INTERFACE
SLAVE IMPULSE LINE
RELAY
LAN MODULE
DESIGN
ADDITIONAL SYNCHRONIZATION
INPUT FOR THERMOMETER
For request
Price on request
Product number 10030000
Do you need help? We are online. Write a message on facebook

BASIC TYPE DIVISION:

Master clock D201 is available in:
  • Standard - STD, with mp3 player - MP3, with power backup - UPS, for use in big time distribution systems - MAX
  • Rack - RQ or wall -mounted  - PQ version
  • Input slot for GPS receiver and C232 interface to connect with PC.
  • Master clock with interface 485 can be synchronized from NTP using D213 converter
NOTE: GPS input can be used to connect GPS or DCF receiver.

D201RQ/UPS CHARACTERISTICS:
  • 1 slave link - suitable for small time distribution systems
  • ACTIVE ENERGY BACKUP with accumulator 2x12V/2.2Ah. During power cut system remains operational (including slave clocks)
  • Metal casing compatible with 19 inches rack system or table version with shorter front panel to be situated on the table.
  • Can work independently, without synchronization from outside.
  • Input slot for GPS receiver providing high accuracy. For example GPS receiver D910SQ.
  • C232 interface to connect with PC. It is possible to use USB virtual COM converter.
  • Synchronization from link 485 can be added. It is bi-directional interface. It is possible to use to set up slave clock with time from master clock or to set up master clock time from superior master clock device.
  • The master clock can be extended with a wireless DHF system with D216 converter.
MINIMAL CONFIGURATION
  • One slave polarized link 24VDC (minute or second)
  • Active energy backup
  • Rack version
  • 35W power supply (one slave link)
CONFIGURABLE OPTIONS

C485 INTERFACE:
  • NO - interface is not used
  • YES - It is possible to synchronize connected devices (digital clocks, other master clocks ) or be synchronized from another device.
VERSION:
  • RACK - compatible with 19" rack system. Handles are used.
  • TABLE - front panel is shorter. Handles are not used. Better version to be situated on a table or shelf.
SLAVE LINK:
  • 1X - at least one link is always used.
  • 2X - used with stronger power supply (60 W)
  • 3X - used with stronger power supply (60 W)
NOTE: Each slave polarized link is for voltage 24 VDC and has electronic current overload protection set to 0,5 A. Selection of minute/second mode with jumper on link board.

RELAY:
  • NO - not used
  • RELAY1 - One contact switch voltage 24 VDC (e.g. for engine bells). Other contact is made separately (marked as RELAY1 NC).

SLAVE LINK INPUT
  • NO - not installed
  • YES -  It is possible to use to set up master clock time from superior master clock device.
INPUT FOR THERMOMETER
  • NO - not installed
  • YES - it allows to connect thermometer (e.g. D111SQ). TInformation about temperature can be distributed into slave clocks using C485 or second polarized link.
8xRELAY MODULE
  • NO - not installed
  • YES enables to switch 8 relay based on time settings. 24V voltage use only.
LAN MODULE
  • NO - not installed
  • YES - Remote control through LAN with MonTIME PC application (for windows).